Overview:
This Technical Bulletin describes how to set the parameters for Delta VFD-B series inverter.
To program the Delta Inverter programming parameters:
Each Delta inverter parameter has 2 set of numbers. Example: 01-02. We will call 01 “Group Parameter” and 02 “Parameter Number.”
1. Press "PROG"
2. Press the up or down arrow key to select the group parameter.
3. Press “PROG”
4. Press the up or down arrow key to select the parameter number.
5. Press “PROG”. At this time parameter value should be blinking. Use arrow key to change the value.
6. Press “PROG” again to save parameter values or “Mode” to discard.
7. Continue until all the parameters have been set.
Delta Inverter Parameter Settings
Model: VFD-B
00-08 set 00
00-09 set 00
01-00 set 103.6 Hz (KL-2160 Maxima 1500rpm) depend on maxima speed rpm.
01-01 set 60Hz
01-02 set 220v
01-09 set 3’s
01-10 set 3’s
02-00 set 01
02-01 set 01
02-02 set 00
02-03 set 09 (for 5.5kw to 18.5kw)
set 15 (for 0.75 to 3.7Kw)
02-04 set 00
02-05 set 00
03-01 set 24