INVERTER DELTA VFD-B
(NONE ATC VERTICAL MACHINE AND CNC LATHES MACHINE)
To program the Delta Inverter programming parameters:
Each Delta inverter parameter has 2 set of numbers. Example: 01-02. We will call 01 “Group Parameter” and 02 “Parameter Number.”
1. Press "PROG"
2. Press the up or down arrow key to select the group parameter.
3. Press “PROG”
4. Press the up or down arrow key to select the parameter number.
5. Press “PROG”. At this time parameter value should be blinking. Use arrow key to change the value.
6. Press “PROG” again to save parameter values or “Mode” to discard.
7. Continue until all the parameters have been set.
Delta Inverter Parameter Settings
Model: VFD-B
Par 00-08 set 00
00-09 set 00 ( V/F mode)
01-00 set 145 Hz for B3EC - 6000 RPM
157 Hz for B3FC, B5FC, B6FC -4000 RPM.
169 Hz for 3VK – 5000RPM.
134 Hz for E5FC Plus -4000rpm
104.3 HZ FOR KL-21 AND KL-30 SERIES (2000 RPM)
110 HZ FOR KL-16 SERIES (3000 RPM)
01-01 set 60 Hz
01-02 set 220V
01-09 set 3’s
01-10 set 3’s
02-00 set 01
02-01 set 01
02-02 set 00
02-03 set 15 (for 0.75 to 3.7kw -3VK,B3EC,B6FC…).
Set 09 (for 5.5 to 18.5kw-B8EC, KL 1640…).
02-04 set 00
02-05 set 00
02-10 set 00
02-11 set 00
02-12 set 00
02-13 set 00
02-14 set 00
03-01 Multi-Function Output Terminal MO1 3
03-02 Multi-Function Output Terminal MO2 24
Parameter 03-01 and 03-02 is used for Zero Speed