Setting Delta Inverter VE With Different Ratio Motor Pulley and Spindle Pulley
Some customer wants to upgrade spindle more power, they change pulley of motor smaller (32 tooth). Atrump ‘s machine, ratio of motor pulley and spindle pulley is 1:1 (pulleys: 48 tooth).
Changing pulley of motor is 32 tooth, and pulley of spindle is 48 tooth so ratio 1:1.5, and spindle maxima RPM is 4000 (6000/1.5=4000).
Centroid control: F1 [set up] → F3 [config] → 137 enter → F1 [control] change maxima high gear RPM is 4000.→ F10 [save].
Delta inverter -VE
Set parameter 10-27 is 32 (pulley of motor 32 T).
10-28 is 48 (pulley of spindle 48T).
After that, doing Auto turn and set Spindle Orientaion.
Look procedure to set inverter Delta -VE